PREVECTRON®
2 - E. S. E. Lightning Conductors |
| |
|
| |
| AVKO JSC offers lighting-protectors
PREVECTRON® 2, produced by INDELEC®
- France and we are the one and only representative for Bulgaria of
this product. |
|
| |
 |
|
Key
benefits
The skills of INDELEC’s engineers, the variety of tests carried out in both
high-voltage laboratories and real-life lightning conditions, and the experience
gained from the thousands of PREVECTRON®2 installations around the world,
have allowed us to develop a complete range of lightning conductors offering
a host of key benefits: |
- 6-model range offering customized solutions for each project (easthetic
constraints, required protection area, etc.)
- fully autonomous operation
- total reliability, even in extreme climatic conditions
- proven, robust design able to withstand multiple lightning strikes
- lightning conductor only becomes active when electrical field intensity
rises (lightning discharge likely), the PREVECTRON®2 presents no
danger to the site
- straightforward installation & maintenance using tools specially
developed by INDELEC, including protection calculation software, strike
counter and PREVECTRON® tester
- high-voltage laboratory test results available on request
- real-life test results & scientific reports available on request
- ultra-safe capture tip thanks to full electrical continuity between
the tip and the earth point
- ISO 9001-2000 manufacturing process (certificate No.116884)
|
Protection
area
The protection area Rp of a PREVECTRON®2 lightning conductor is calculated
according to French Standard NF C 17-102, thus
The protection area depends on a number of factors: |
- Gain in triggering time
T(µs) of the chosen PREVECTRON®2
L(m) = V(m/µs); V* = 1 m/µs
T* |
S 6.60 |
S 4.50 |
S 3.40 |
TS 3.40 |
TS 2.25 |
| 60 |
50 |
40 |
40 |
25 |
*
values obtained through tests conducted in high voltage laboratories.
- D(m) = 20, 45, or 60, depending on the protection level required (I,
II, or III) on a given site, according to the lightning risk assessment
guide.
- the actual height of the lightning air terminal above the surface
to be protected:
h (where h < 5 m, for Rp see table below).
|
| Protection
Radii |
Level I : D=20m
high protection |
| h(m) |
2 |
3 |
4 |
5 |
10 |
| S 6.60 |
31 |
47 |
63 |
79 |
79 |
| S 4.50 |
27 |
41 |
55 |
68 |
69 |
| S 3.40 |
23 |
35 |
46 |
58 |
59 |
| TS 3.40 |
23 |
35 |
46 |
58 |
59 |
| TS 2.25 |
17 |
25 |
34 |
42 |
44 |
| TS 2.10 |
10 |
15 |
21 |
26 |
26 |
|
Level II : D=45m
medium protection |
| h(m) |
2 |
3 |
4 |
5 |
10 |
| S 6.60 |
39 |
58 |
78 |
97 |
99 |
| S 4.50 |
34 |
52 |
69 |
86 |
88 |
| S 3.40 |
30 |
45 |
60 |
75 |
77 |
| TS 3.40 |
30 |
45 |
60 |
75 |
77 |
| TS 2.25 |
23 |
34 |
46 |
57 |
61 |
| TS 2.10 |
15 |
22 |
30 |
38 |
38 |
|
Level III : D=60m
standard protection |
| h(m) |
2 |
3 |
4 |
5 |
10 |
| S 6.60 |
43 |
64 |
85 |
107 |
109 |
| S 4.50 |
38 |
57 |
76 |
95 |
98 |
| S 3.40 |
33 |
50 |
67 |
84 |
87 |
| TS 3.40 |
33 |
50 |
67 |
84 |
87 |
| TS 2.25 |
26 |
39 |
52 |
65 |
69 |
| TS 2.10 |
17 |
26 |
34 |
43 |
44 |
|
| |
|
| |
|